Abstract
A mathematical model is proposed in this paper for locating optimal positions for passive energy dissipative dampers. Three control indices of structural responses with the storey-drift angle, storey displacement, and acceleration are taken in this model. Firstly, six combination modes of these indices are presented. On the premise that the number of dampers is fixed, this paper deals with the optimal placement of two types of passive dampers for several building models with different number of storeys and seismic ground motions at four types of sites using genetic algorithm. Secondly, two estimating indices are presented to assess the reasonable combination mode of coefficients under different conditions, which can generally express the best response control. Numerical examples are illustrated to verify the effectiveness and feasibility of the proposed mathematical model. At last, several significant conclusions are given based on numerical results.